Résumé
An enzymatic method using nitrocefin as substrate was developed to assay sulbactam in human serum. Serum containing sulbactam was incubated with purified titrated TEM-1 β-lactamase and nitrocefin was then added to the mixture to determine the remaining β-lactamase activity and consequently the concentration of sulbactam. Assays were carried out on five patients with pulmonary infections receiving sulbactam plus amoxycillin iv. The values for serum sulbactam concentrations determined by the enzymatic method were compared with those determined by high performance liquid chromatography (HPLC). The correlation coefficient was 0·990 for serum sulbactam concentrations below 15 mg/L.