Logo image
Se connecter
A French multicenter analytical evaluation of the automated Lumipulse G sNfL blood assay (Fujirebio®) and its comparison to four other immunoassays for serum neurofilament light chain assessment in clinical settings
Article de revue   Open Access   Avec comité de lecture

A French multicenter analytical evaluation of the automated Lumipulse G sNfL blood assay (Fujirebio®) and its comparison to four other immunoassays for serum neurofilament light chain assessment in clinical settings

Etienne Mondésert, Susanna Schraen-Maschke, Isabelle Quadrio, Olivier Bousiges, Damien Bouvier, Constance Delaby, Aurélie Bedel, Sylvain Lehmann et Anthony Fourier
Clinica Chimica Acta, Vol.565
15/01/2025
PMID: 39454987

Résumé

Neurological and neurodegenerative diseases Neurofilament light chain Immunoassay Humans Neurofilament Proteins France Automation Blood Chemical Analysis
Measurement of serum neurofilament light chain (sNfL) protein is becoming a key biomarker for many neurological diseases. Several immunoassays have been developed to meet these clinical needs, revealing significant differences in terms of variability and results. Here, we propose a French multicenter comparison of 5 sNfL assays.

Fichiers et liens (2)

url
Find in HALAfficher
url
https://doi.org/10.1016/j.cca.2024.120007Afficher
Published (Version of record) Ouvrir

Indicateurs

1 Consultations de la notice

Détails

Logo image