Abstract
The work presented in this thesis concerns the use of time techniques for impulsive ElectroMagnetic Compatibility (EMC) applications, mainly for Modes Stirred Reverberation Chamber (MSRC) studies. Contrary to approaches from frequency domain, obviously well-fitted for studies in resonant cavities, the main idea of this thesis was to study an original time method for MSRC investigation to propose new paradigms for equipment characterization. Originally developed in acoustics, the Time Reversal (TR) process recently applied to electromagnetic waves allows focusing it both in time and space. The process quality is even higher if the propagation environment is reverberant. Thus, the Reverberation Chambers (RC) are an ideal locations for TR implementation. After a study of parameters involved in the TR process coupled with the definition of specific numerical methods, the applications of TR in MSRC are exposed. In particular, the interest of selective focusing for radiated susceptibility tests is demonstrated. The importance of absorption and diffraction coefficients for MSRC equipment justifies their accurate and efficient characterization. To this end, the implementation of a temporal calculation of the Total Scattering Cross Section (TSCS) in RC is detailed. The application of this new technique to different forms of stirrers allows finally to face these results with those obtained from standard EMC test.