Logo image
Thermal deflection decoupled 6-DOF pose measurement of hexapods
Acte de colloque   Open Access

Thermal deflection decoupled 6-DOF pose measurement of hexapods

Vinayak Jagannathrao Kalas, Alain Vissière, Olivier Company, Sébastien Krut, Pierre Noiré, Thierry Roux et Francois PIERROT
EUSPEN 2020 - 20th International Conference of the European Society for Precision Engineering and Nanotechnology (Geneva, Switzerland, 08/06/2020–12/06/2020)
2020

Résumé

Pose measurement Accuracy Thermal error Hexapod Positioning system
Calibration is crucial for hexapods with high-accuracy positioning capability. Many of these calibration procedures require measurement of hexapod's platform pose (position and orientation) at constant temperature. Consequently, thermal deflection of the hexapod's platform during pose measurements impacts the accuracy of calibrated parameters. This paper presents a method to eliminate the impact of thermal deflection of hexapods on their pose measurement. In this method, a reference pose is measured before each measurement of any particular pose. The measurements of reference pose are used to estimate thermal deflection of hexapod's legs. This is in turn used to estimate and correct the resulting pose error at the particular pose to be measured. The advantage of using the proposed method is demonstrated experimentally by means of pose measurements of a high-precision hexapod using a CMM.