Résumé
The paper presents a study of the dynamic response of an Automatic Gain Control (AGC) loop exposed to a pulsed radiofrequency intentional interference. The influence of the various parameters of the pulse on its behavior is investigated, and a comprehensive model replicating the observed effects is presented. It is demonstrated that the pulse duration optimizing the susceptibility studied here is directly linked to the settling time of the AGC.